One second from sensor to chart
The on-site gateway polls inverters, meters and BMS over Modbus and IEC 104, buffers data during link outages and backfills it without gaps.
- poll step
- 1 s
- gateway buffer
- 72 h
- to cloud
- ≤ 4 s
FAZOR collects telemetry from inverters, strings and batteries every second, finds losses and schedules charging by market price. For O&M engineers and CTOs running more than one plant.
The on-site gateway polls inverters, meters and BMS over Modbus and IEC 104, buffers data during link outages and backfills it without gaps.
Every string gets a model of expected current from irradiance and module temperature. A deviation above 6 % that lasts 20 minutes becomes a ticket with a map position and a likely cause.
The dispatcher plans the battery schedule a day ahead from market prices and the generation forecast, keeps headroom for grid limits and tracks cell degradation every cycle.
P10–P90 for 48 hours from numerical weather prediction and satellite cloud cover. Yesterday’s error is computed every morning and shown next to the forecast.
REST and an MQTT stream with the same IDs as the interface. Webhooks for tickets, history export to Parquet, keys scoped per plant.
$ curl -s api.fazor.example/v4/sites/SOL-ODS-07/strings \
-G -d 'dev=lt:-0.06' -H "Authorization: Bearer $KEY"
HTTP/2 200 · 38 ms
[
{ "id": "STR-04.18", "inv": "INV-05", "dev": -0.182,
"cause": "soiling", "since": "2026-10-09T09:12Z" },
{ "id": "STR-08.05", "inv": "INV-02", "dev": -0.410,
"cause": "bypass_diode", "ticket": "OPS-2291" }
]
of installed capacity under watch
from 500 kW rooftops to 200 MW parks
telemetry step — no averaging on the gateway
of yield recovered on average in year one
We connect to what is already installed. Data can stay inside your network.
| protocol | what we poll | mode |
|---|---|---|
| Modbus TCP/RTU | inverters, meters, weather stations | poll 1 s |
| IEC 60870-5-104 | telecontrol, grid dispatcher | spontaneous |
| IEC 61850 MMS | substation, protection relays | reports |
| SunSpec | inverters by model | poll 1 s |
| MQTT · Sparkplug B | gateways, BMS | stream |
| OPC UA | existing SCADA | subscription |
We mount the gateway in the comms cabinet, map the registers and get first telemetry the same day.
We calibrate expected current on two weeks of data and switch on loss tickets.
First as an advisor, then an automatic schedule within the grid operator’s limits.
An on-call engineer, a monthly loss report and a review of every outage.
Send us the capacity and equipment list — within a week we connect one plant in read-only mode.
Portfolio demo: the brand is fictional, requests are not sent anywhere.
Per-second telemetry from inverters, strings and batteries, loss detection and market-price charging.
The gateway polls equipment over Modbus and IEC 104 and keeps 72 hours of buffer in case the link drops.
336 strings. Tap an orange cell to open the loss card.
Portfolio demo: the brand is fictional, requests are not sent anywhere.